技術支援
IEC標準
Appliance Coupler Number of Standard Sheet for | Infomations | |
Appliance Inlet | Connector |

C 2

C 1
Rated current of appliance coupler (A)
0.2Class of equipment
IIMaximum temperature of appliance inlet
70℃Rewirable construction allowed
NoLightest type allowed
60227 IEC 41Minimum cross-section (mm)
--(1)Standard sheet of IEC 60083
A 1-15 , B , C 5
C 6

C 5
Rated current of appliance coupler (A)
2.5Class of equipment
IMaximum temperature of appliance inlet
70℃Rewirable construction allowed
NoLightest type allowed
60227 IEC 52Minimum cross-section (mm)
0.75Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 4
C 8

C 7
Rated current of appliance coupler (A)
2.5Class of equipment
IIMaximum temperature of appliance inlet
70℃Rewirable construction allowed
NoLightest type allowed
60227 IEC 52Minimum cross-section (mm)
0.75(2)Standard sheet of IEC 60083
A 1-15 , B 2 , C 5 , C 6
C 10

C 9
Rated current of appliance coupler (A)
6Class of equipment
IIMaximum temperature of appliance inlet
70℃Rewirable construction allowed
NoLightest type allowed
60227 IEC 52Minimum cross-section (mm)
0.75Standard sheet of IEC 60083
A 1-15 , B 2 , C 6
C 14

C 13
Rated current of appliance coupler (A)
10Class of equipment
IMaximum temperature of appliance inlet
70℃Rewirable construction allowed
YesLightest type allowed
60227 IEC 53 or 60245 IEC 53Minimum cross-section (mm)
0.75(3)Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
C 16

C 15
Rated current of appliance coupler (A)
10Class of equipment
IMaximum temperature of appliance inlet
120℃Rewirable construction allowed
YesLightest type allowed
60245 IEC 53 or 60245 IEC 51Minimum cross-section (mm)
0.75(3)Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
C 16A

C 15A
Rated current of appliance coupler (A)
10Class of equipment
IMaximum temperature of appliance inlet
155℃Rewirable construction allowed
YesLightest type allowed
60245 IEC 53 or 60245 IEC 51Minimum cross-section (mm)
0.75(3)Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
C 18

C 17
Rated current of appliance coupler (A)
10Class of equipment
IIMaximum temperature of appliance inlet
70℃Rewirable construction allowed
NoLightest type allowed
60227 IEC 53 or 60245 IEC 53Minimum cross-section (mm)
0.75(3)Standard sheet of IEC 60083
A 1-15 , B 2 , C 6
C 20

C 19
Rated current of appliance coupler (A)
16Class of equipment
IMaximum temperature of appliance inlet
70℃Rewirable construction allowed
YesLightest type allowed
60227 IEC 53 or 60245 IEC 53Minimum cross-section (mm)
1(3)Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
C 22

C 21
Rated current of appliance coupler (A)
16Class of equipment
IMaximum temperature of appliance inlet
155℃Rewirable construction allowed
YesLightest type allowed
60245 IEC 53 or 60245 IEC 51Minimum cross-section (mm)
1(3)Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
C 24

C 23
Rated current of appliance coupler (A)
16Class of equipment
IIMaximum temperature of appliance inlet
70℃Rewirable construction allowed
NoLightest type allowed
60227 IEC 53 or 60245 IEC 53Minimum cross-section (mm)
1(3)Standard sheet of IEC 60083
A 1-15 , B 2 , C 6- (1)Only for small hand-held appliances, in length not exceeding 2 m, if allowed by the relevant appliance standard.
- (2)0,5 mm2 is allowed for lengths not exceeding 2 m.
- (3)If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be
- 1 mm2 for 10 A connectors
- 1.5 mm2 for 16 A connectors