Header 1

HomeTechnical Support

IEC 60320 Connector Chart

Appliance Coupler Number of Standard Sheet forInfomations
Appliance InletConnector
*
C 2
*
C 1

Rated current of appliance coupler (A)

0.2

Class of equipment

II

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

No

Lightest type allowed

60227 IEC 41

Minimum cross-section (mm)

--(1)

Standard sheet of IEC 60083

A 1-15 , B , C 5
*
C 6
*
C 5

Rated current of appliance coupler (A)

2.5

Class of equipment

I

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

No

Lightest type allowed

60227 IEC 52

Minimum cross-section (mm)

0.75

Standard sheet of IEC 60083

A 5-15 , B 2 , C 2b , C 4
*
C 8
*
C 7

Rated current of appliance coupler (A)

2.5

Class of equipment

II

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

No

Lightest type allowed

60227 IEC 52

Minimum cross-section (mm)

0.75(2)

Standard sheet of IEC 60083

A 1-15 , B 2 , C 5 , C 6
*
C 10
*
C 9

Rated current of appliance coupler (A)

6

Class of equipment

II

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

No

Lightest type allowed

60227 IEC 52

Minimum cross-section (mm)

0.75

Standard sheet of IEC 60083

A 1-15 , B 2 , C 6
*
C 14
*
C 13

Rated current of appliance coupler (A)

10

Class of equipment

I

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

Yes

Lightest type allowed

60227 IEC 53 or 60245 IEC 53

Minimum cross-section (mm)

0.75(3)

Standard sheet of IEC 60083

A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 16
*
C 15

Rated current of appliance coupler (A)

10

Class of equipment

I

Maximum temperature of appliance inlet

120℃

Rewirable construction allowed

Yes

Lightest type allowed

60245 IEC 53 or 60245 IEC 51

Minimum cross-section (mm)

0.75(3)

Standard sheet of IEC 60083

A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 16A
*
C 15A

Rated current of appliance coupler (A)

10

Class of equipment

I

Maximum temperature of appliance inlet

155℃

Rewirable construction allowed

Yes

Lightest type allowed

60245 IEC 53 or 60245 IEC 51

Minimum cross-section (mm)

0.75(3)

Standard sheet of IEC 60083

A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 18
*
C 17

Rated current of appliance coupler (A)

10

Class of equipment

II

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

No

Lightest type allowed

60227 IEC 53 or 60245 IEC 53

Minimum cross-section (mm)

0.75(3)

Standard sheet of IEC 60083

A 1-15 , B 2 , C 6
*
C 20
*
C 19

Rated current of appliance coupler (A)

16

Class of equipment

I

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

Yes

Lightest type allowed

60227 IEC 53 or 60245 IEC 53

Minimum cross-section (mm)

1(3)

Standard sheet of IEC 60083

A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 22
*
C 21

Rated current of appliance coupler (A)

16

Class of equipment

I

Maximum temperature of appliance inlet

155℃

Rewirable construction allowed

Yes

Lightest type allowed

60245 IEC 53 or 60245 IEC 51

Minimum cross-section (mm)

1(3)

Standard sheet of IEC 60083

A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 24
*
C 23

Rated current of appliance coupler (A)

16

Class of equipment

II

Maximum temperature of appliance inlet

70℃

Rewirable construction allowed

No

Lightest type allowed

60227 IEC 53 or 60245 IEC 53

Minimum cross-section (mm)

1(3)

Standard sheet of IEC 60083

A 1-15 , B 2 , C 6
  1. (1)Only for small hand-held appliances, in length not exceeding 2 m, if allowed by the relevant appliance standard.
  2. (2)0,5 mm2 is allowed for lengths not exceeding 2 m.
  3. (3)If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be
    - 1 mm2 for 10 A connectors
    - 1.5 mm2 for 16 A connectors