IEC 60320 Connector Chart

Appliance Coupler
Number of Standard Sheet for
Infomations
Appliance Inlet Connector
*
C 2
*
C 1
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
0.2 II 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
No 60227 IEC 41 --(1)
Standard sheet of IEC 60083
A 1-15 , B , C 5
*
C 6
*
C 5
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
2.5 I 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
No 60227 IEC 52 0.75
Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 4
*
C 8
*
C 7
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
2.5 II 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
No 60227 IEC 52 0.75(2)
Standard sheet of IEC 60083
A 1-15 , B 2 , C 5 , C 6
*
C 10
*
C 9
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
6 II 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
No 60227 IEC 52 0.75
Standard sheet of IEC 60083
A 1-15 , B 2 , C 6
*
C 14
*
C 13
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
10 I 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
Yes 60227 IEC 53 or 60245 IEC 53 0.75(3)
Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 16
*
C 15
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
10 I 120℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
Yes 60245 IEC 53 or 60245 IEC 51 0.75(3)
Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 16A
*
C 15A
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
10 I 155℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
Yes 60245 IEC 53 or 60245 IEC 51 0.75(3)
Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 18
*
C 17
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
10 II 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
No 60227 IEC 53 or 60245 IEC 53 0.75(3)
Standard sheet of IEC 60083
A 1-15 , B 2 , C 6
*
C 20
*
C 19
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
16 I 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
Yes 60227 IEC 53 or 60245 IEC 53 1(3)
Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 22
*
C 21
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
16 I 155℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
Yes 60245 IEC 53 or 60245 IEC 51 1(3)
Standard sheet of IEC 60083
A 5-15 , B 2 , C 2b , C 3b , C 4
*
C 24
*
C 23
Rated current of appliance coupler (A) Class of equipment Maximum temperature of appliance inlet
16 II 70℃
Rewirable construction allowed Lightest type allowed Minimum cross-section (mm)
No 60227 IEC 53 or 60245 IEC 53 1(3)
Standard sheet of IEC 60083
A 1-15 , B 2 , C 6
(1)

Only for small hand-held appliances, in length not exceeding 2 m, if allowed by the relevant appliance standard.

(2)

0,5 mm2 is allowed for lengths not exceeding 2 m.

(3)

If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be
- 1 mm2 for 10 A connectors
- 1.5 mm2 for 16 A connectors